Grounding Control Device EKX-4

Grounding Control Device EKX-4

Monitored grounding during loading and unloading of inflammable liquids or solids in tank trucks, silo trucks, and railway wagons.

excl. VAT plus shipping costs

Add to quote

Description

  • Monitored grounding during loading and unloading inflammable liquids or solids in tank trucks, silo trucks and railway wagons
  • For use in gas and dust hazardous areas of zone 1 (equipment category II 2 G) and 21 (II 2 D)
  • Prevents manipulation due to object recognition
  • Controlled derivation of the static electricity
  • Immediate interruption of the loading operation when unsafe grounding connection occurs
  • According to all currently relevant EMC and ATEX directives
  • High functional safety according to EN 61508 / SIL 2 (Hardware-Assessment)

Click on the button below to load the content of timmtechnology.autodesk360.com.

Load Content

Contact Person

TIMM Support Zelck

Do you have questions about the product?

Do you have questions about the product or the TIMM-Onlineshop? Please contact me!

Dr. Alexander Zelck
Sales & Product Lead Gas-Ex

write an E-Mail
+49 (0) 40 248 35 63 – 31

Benefits

  • Prevents manipulation due to object recognition (by measuring the impedance)
  • Opening of the housing during operation in gas-hazardous areas is allowed
  • Automatic diagnosis system self-monitors all safety-related functions continuously
  • Due to the cable compensation, it is also possible to connect cables up to 30 m
  • NAMUR-compatible Ex i control output

Technical Specifications

Type of Protection:According to ATEX-standard 2014/34/EU:
Ex II 2 G – Ex eb q [ib] IIC T4 Gb
Ex II 2 D – Ex tb [ib] IIIC T80°C Db
EC Type Examination:TÜV 11 ATEX 080882
Power Supply:230 V AC ± 10 %, 50 Hz, ca. 10 VA
type of protection “increased safety“ Ex eb
Measuring Circuit:Max. Uo = 6, 7 V; Io = 68 mA; Po = 114 mW
Max. 50 m (ex related specification, functional limitations must be observed)
Type of protection Ex ib / ibD
Only for connection of the grounding cable
The measuring circuit is grounded
Contact Release Output:Switching power max 250 VAC 3 A 100 VA
Type of protection “increased safety“ Ex eb
2 voltage free closing contact, internal monitored
Auxiliary Output:Switching power max. 250 VAC 3 A 100 VA
Type of protection “increased safety“ Ex eb
voltage free changeover contact, not monitored
Electronic Release Output:Max. Ui = 20 V Ii = 20 mA Pi = 400 mW
Inner capacitances Ci negligibly small
Inner inductances Li negligibly small
Type of protection “intrinsic safety“ Ex ib
1 NAMUR-compatible transistor output
Internal resistance: 1 kΩ or 11 kΩ
Modulation: 10 Hz, duty factor 1:1
Protection of Enclosure:IP65
Operation Temperature:– 30 °C up to + 60°C
Dimensions (W x L x H):170 mm x 306 mm x 110 mm
Weight:approx. 4.5 kg

Downloads